Onboard Passenger
Information Displays
Built to rail-grade standards, open to any PIS.
Displays mounted inside rolling stock — door header units and roof-spine ceiling displays for metro, train, and bus saloons.
Rail-grade hardware
for every saloon
Onboard displays live with shock, sustained vibration and wide temperature swing. We build to rail-grade limits — designed and type-tested to EN 50155, EN 45545-2 and IEC 61373 — with screw-lock and M12 connectors that will not work loose over decades. Profiles are slim: door-header units under 25 mm, ceiling units under 50 mm — so they drop into existing vehicle casings during retrofit.
EN 50155 / EN 45545-2 / IEC 61373 type-tested for rolling stock.
Under 25 mm (door header) / under 50 mm (ceiling) to fit existing casings.
−25°C to +70°C operating range for all climate zones.
Qualified to the standards that matter
Five questions every rail buyer asks — answered in one place: standards, shock, fire, readability and integration.
Rail-grade engineering, not industrial-by-guess
EN 50155 is the European standard for electronic equipment on rolling stock. It defines the environmental and electrical envelope a device must survive inside a vehicle — wide temperature swing, a fluctuating DC supply, EMC, and the mechanical duty of the track. We engineer the display to that envelope rather than bolting industrial specs onto a screen and calling it rail-ready.
The standard is more than a single number. Its temperature classes run T1 (−25 °C to +55 °C), T2 (−40 °C to +55 °C), T3 (−25 °C to +70 °C) and TX (−40 °C to +85 °C); carriage-mounted displays typically sit in T1–T3. The DC supply is never clean: EN 50155 requires continuous operation across 0.7–1.25× nominal, ride-through of transients to 0.6× at 100 ms and 1.4× at 1 s, and hold through brief supply interruptions. Nominal rails are 24, 48, 72 and 110 VDC — so a wide-input power stage is mandatory, not optional.
And EN 50155 is never alone. A credible rail display also answers EN 50121-3-2 (EMC), EN 50124-1 (insulation coordination), EN 50125-1 (ambient environment), EN 45545-2 (fire) and IEC 61373 (shock and vibration). A datasheet that names only “EN 50155” but stays silent on the companions has not been fully qualified. We design to the whole set; vehicle-level type approval is completed by the system integrator.
Survives the track, not just the bench
Every kilometre of rail vibrates the carriage body; every passing train transmits low-frequency shock through the structure. IEC 61373 grades this by where the equipment is mounted: Category 1 (body-mounted, split into 1A direct and 1B inside a box), Category 2 (bogie-mounted) and Category 3 (axle-mounted), with severity rising 1 → 2 → 3. A saloon display is body-mounted, so it is qualified to Category 1 — typically Class 1B.
Qualification is not a single shake. IEC 61373 sequences a functional random-vibration test (powered, at least 10 minutes per axis), a simulated long-life test (around 15 hours total, 5 hours per axis, to prove structural integrity), and half-sine shock pulses. We pair this with EPDM dampening gaskets at the panel-to-enclosure interface — they absorb the shockwaves and seal against moisture — and screw-lock M12 I/O that cannot walk loose over a decade of service.
Low smoke, low toxicity, by design
Inside a confined carriage, a fire is a smoke-and-toxicity event before it is a flame event. EN 45545-2 sets the fire behaviour of materials and components on railway vehicles. It sorts materials into 26 end-use categories (R1–R26) and three hazard levels — HL1 (lowest), HL2 and HL3 (strictest, and mandatory for new EU metro projects). The tests measure smoke density (IEC 61034-2), flame spread (IEC 60332) and toxicity (EN 50305); low-smoke zero-halogen (LSZH) compounds are required at every level.
We specify fire-retardant, low-smoke enclosures and harnesses so the display contributes as little to the fire load as the vehicle’s hazard level demands. The exact HL the project needs is set by the operator and the line’s operation category — we build to meet it and confirm the rating on request.
Bright enough, never blinding
A carriage interior is a controlled-lighting environment. Ceiling displays sit comfortably at 500–1,000 nits; door-area and side panels at 400–700 nits. Only door headers facing a sunlit vestibule need to climb toward 1,500 nits — and even there we stay well under our 5,000-nit ceiling. (We build LCD only; the old dot-matrix LED boards are legacy reference, not our product.)
An ambient-light sensor auto-dims the panel at night, cutting power and preventing eye fatigue on a 30-minute ride. Brightness is a comfort and contrast problem in here, not a sunlight-war.
Open hardware, your software
Each unit ships with screw-lock M12 I/O, Ethernet and a wide 24–110 VDC input, plus an open SDK/API. Your existing PIS, CMS or signage controller drives the screen — we do not lock you into a stack, and we do not sell software. We are a display-hardware manufacturer; the navigation, ticketing and passenger-information logic stays with you or your integrator.
That split is deliberate. We own the panel, the enclosure, the thermal path and the rail-grade qualification. You own the content and the system around it. Integration is a cable and an API, not a negotiation.
Two form factors, one standard
Both share the same rail-grade build, open interfaces and slim profiles. Choose by mount point.
Door Header Displays
Ultra-slim stretched LCD units mounted above carriage doorways. 19"–43" bars showing next-stop, route maps and exit side. Depth under 25 mm.
Ceiling Mount Displays
Dual-face overhead screens mounted on the roof spine. Single or double-sided, showing route maps and advertising along the saloon. Depth under 50 mm.
Engineering Checklist
Representative specification, confirmed per OEM/ODM project.
| Parameter | Door Header | Ceiling Mount |
|---|---|---|
| Form factor | 19"–43" stretched bar | 15"–32" dual-face |
| Depth | <25 mm | <50 mm |
| Brightness | 500–1,500 nits | 500–1,500 nits |
| Ingress | IP65 front | IP54 (indoor) |
| Temperature | −25°C to +70°C | −25°C to +70°C |
| Rail standards | EN 50155 / 45545 / 61373 | EN 50155 / 45545 / 61373 |
| Power & I/O | 24–110VDC, M12, Ethernet | 24–110VDC, M12, Ethernet |
| Contrast / viewing | ≥1000:1 / ≥170° | ≥1000:1 / ≥170° |
| Backlight life | up to 50,000 h (L50) | up to 50,000 h (L50) |
| Warranty | 3-year standard + long-cycle after-sales | 3-year standard + long-cycle after-sales |
Used across every rail mode
Built for the long haul, backed for longer
Service life
Several factors shape a display’s working life — the LED backlight, the panel, the driver electronics and the duty environment among them. Industrial WLED backlights are rated to about 50,000 hours to half brightness (L50); we reference this as an industry baseline rather than promise a fixed lifespan. Our units are rated to an MTBF of 50,000 hours, based on our reliability test data; the figure for your configuration is on the datasheet rather than a category-average assumption.
Warranty & after-sales
Our standard warranty is 3 years, and we back it with long-cycle after-sales service: wherever a unit fails, we repair it — a swapped board or module rather than a replaced unit. Fewer truck rolls, a smaller spare-parts bin, and a display that keeps earning its place on the vehicle.
Frequently asked
Everything you need to know about specifying Onboard Passenger Information Displays hardware.
01
What rail certifications do onboard units carry?
Designed and type-tested to EN 50155, EN 45545-2 and IEC 61373 (Category 1); CE / RoHS / FCC and ISO 9001 certified. Vehicle-level type approval is completed by the system integrator.
02
Will these retrofit into existing vehicles?
Yes. Slim profiles drop into existing casings; M12 and screw-lock connectors match standard looms. Send us the casing drawing and we confirm fit.
03
Can we keep our current PIS software?
Yes. Open SDK/API and standard interfaces let your existing PIS/CMS drive the screens; no locked stack.
04
What's the difference between door header and ceiling mount?
Door header units are stretched bars (19"–43") mounted above doorways, showing next-stop and route maps. Ceiling units are dual-face screens (15"–32") mounted on the roof spine, visible from both sides of the saloon.
05
What EN 50155 temperature class do your displays support?
Carriage-mounted displays are qualified across the EN 50155 temperature classes relevant to saloons — commonly T1 (−25 °C to +55 °C) through T3 (−25 °C to +70 °C), selected to match the vehicle’s service climate. Tell us the operating envelope and we confirm the class.
06
Are the displays sunlight-readable for vestibules?
Door-header units facing a sunlit vestibule reach up to 1,500 nits with anti-glare treatment, while interior ceiling and side displays run 400–1,000 nits in controlled lighting. All stay within our 5,000-nit ceiling; we build LCD only.
Specify onboard displays for your fleet.
Share your vehicle types and mount points — we return a rail-grade, slim-profile LCD proposal.